an internal bypass system.
Hoist hydraulic cylinder piston
BSR
SWING, RIGHT & LEFT SIDE
rods shall be chrome plated.
CENTER RACKS
The hoist shall lift the body to a
When code BSR is specified,
minimum dumping angle of 45
the center racks on both sides
degrees measured from the top
shall be the manufacturer's
of the truck chassis frame. The
standard swing type, for easy
hoist shall be capable of
side loading.
lowering the raised body by
gravity when the pump is
BSU
DOUBLE ACTING UNDERBODY
disabled. The controls shall be
TYPE HOIST
located in the truck cab and
shall be accessible to the seated
When code BSU is specified, a
driver.
The location of the
double acting scissors or
controls shall not interfere with
underbody type hoist, with an
the entry and exit of the driver.
internal bypass system, shall be
Hydraulic system and pumping
provided.
unit shall comply with 3.1.1.11.
A mechanical safety lock,
BTC
TOOL COMPARTMENT, STEEL
WITH LATCH
permanently affixed to the body,
When code BTC is specified, a
shall be furnished. The safety
toolbox shall be provided. The
lock shall provide positive
toolbox shall provide for storage
retention of the body in the up
in addition to that required by
position for servicing or repair.
3.4.16.
Minimum dimensions
The safety lock mechanism shall
shall be 457 mm (18 in) by 457
not interfere with the operation
mm (18 in) by 609 mm (24 in).
of the body under any operating
A door opening size of not less
conditions.
than 482 mm (19 in) by 330 mm
BSF2
SMOOTH STEEL FLOOR
(13 in) shall be furnished. The
When BSF2 is specified, smooth
toolbox shall be fabricated of not
steel floors, one or two-piece,
less than 14 gage (2.657 mm)
4.8 mm (3/16 in) thick, shall be
(0.1046 in) steel or of equivalent
provided for the body with
strength aluminum. The toolbox
additional
lateral
support
shall be weatherproof and shall
provided at the wheel wells.
provide for locking. The toolbox
Two-piece floors shall be spliced
shall be mounted as close as
longitudinally and completely
possible to the rear of the cab,
welded the full length of the
on the curbside of the vehicle.
splice. One completely welded
CC
CREW-CAB, 4 DOOR
lateral steel floor splice is
When code CC is specified, a
acceptable on bodies over 4880
four-door, full width crew cab
mm (16 feet) in length.
shall be provided. The cab shall
be
equipped
with
two
upholstered, full width seats and
backs. The front seat shall be
adjustable. With the front seat
adjusted to the extreme forward
Federal Standard 807M
Page 32 of 65
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business