MIL-DTL-62073H(AT)
nanometers (nm), with the following exception: Energy may be radiated in the 700 to
1200 nm band range provided it is less that 1% of the energy radiated in the 380 to
700 nm band. The 24 volt lamp assembly is to include one, yellow, solid state lamp
in the center and a pair of red, solid state lamps on each side of the center lamp. The
four red lamps will appear as individual lights up to 60 feet, from 60 to 120 feet the
four red lights will converge into two points of light. Lights will be visible at 1000,
plus or minus 200 feet. When trailer is on a 20 percent downgrade no light is to be
visible from an altitude which exceeds 400 feet
Light emitting diodes (LEDs). To determine conformance to 3.5.2.5, LEDs shall
e.
operate under SAE J1889 and related electrical harness wires are to be of commercial
design currently being produced and marketed by the supplier, and fully meet the
LED light requirements described herein for one LED running light system,
operational with either 12 or 24 volt.
f.
Electrical harness requirements. To determine conformance to 3.5.2.6, verify that
the wiring is secured to prevent chaffing and loose connections.
Receptacles. To determine conformance to 3.5.2.7, receptacles shall operate with
g.
one 12-contact receptacle with cover, and one 7-contact receptacle with cover
installed at the front of the trailer. Both receptacles are to be located as required by
SAE J702. These receptacles are to be interconnected without the use of circuit
breakers.
Controls. To determine conformance to 3.5.3, controls shall operate without
h.
malfunction, throughout all ranges of operation under all trailer operating conditions.
i.
Adjustment mechanisms. To determine conformance to 3.5.4, adjustment
mechanisms shall operate properly and maintain adjustment settings during all trailer
operating conditions.
j.
Safety chains. To determine conformance to 3.5.5, verify the safety chain assembly
are to drawing 12441163.
Transportability. To determine conformance to 3.5.6, verify the transportability
k.
requirements used for the trailer have been approved.
l.
Lifting/tiedown provisions. To determine conformance to 3.5.6.1, verify the
lifting/tiedown provisions to secure the trailer and cargo during transport and to lift
the vehicle have been approved.
m.
Marine transport. To determine conformance to 3.5.6.2, verify that when coupled to
the prime mover and with a payload equivalent to an empty M1061A1 trailer the
trailer has been approved for marine transport.
n.
Lifting provisions. To determine conformance to 3.5.6.3, verify the lifting
provisions meet the design requirements and have been approved.
Tiedown provisions. To determine conformance to 3.5.6.4, verify the tie-down
o.
provisions have been approved.
p.
Rail transport. To determine conformance to 3.5.6.5, verify the trailer coupled to the
prime mover and with a payload equivalent to that of an empty trailer on TOFC have
been approved for rail transport.