MIL-DTL-62049G
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA Handbook of the National Electric Code
(Copies of this document are available from www.nfpa.org or National Fire Protection
Association, 1 Batterymarch Park, Quincy, MA 02269.)
SAE INTERNATIONAL
SAE J2014
-
(R) Pneumatic Tires for Military Tactical Wheeled Vehicles
(Copies of these documents are available from www.sae.org or SAE Customer Service, 400
Commonwealth Drive, Warrendale, PA 15096-0001.)
2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event
of a conflict between the text of this document and the references cited herein, the text of this
document takes precedence. Nothing in this document, however, supersedes applicable laws and
regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 First article. When specified (see 6.2), a sample shall be subjected to first article
inspection in accordance with 4.2.
3.2 Materials. Unless otherwise specified herein or specified in the applicable drawings,
materials used shall be in accordance with the manufacturer s materials specifications for
semitrailers. The materials shall be capable of meeting all the operational and environmental
requirements specified herein (see 4.5.1). Recovered materials shall be used to the maximum
extent practicable. Materials and special treatments shall be utilized to prevent corrosion and to
resist harmful effects of dust, water and fungi. Dissimilar metals shall not be used in intimate
contact without protection from galvanic corrosion.
3.2.1 Hazardous materials. All hazardous materials including asbestos, cadmium, and
radioactive material shall be eliminated or minimized (where elimination is not possible)
(see 6.8). Radioactive material is defined by CFR, Title 10, Parts 30 and 40, and other
radioactive material in which the specific activity is greater than 0.002 microcuries per gram or
the activity per item equals or exceeds 0.01 microcuries.
3.2.2 Corrosion protection. The vehicle shall be fabricated from compatible materials
providing corrosion protection and coating adherence equal to or exceeding that provided by hot
dip galvanized 1010 steel with a minimum coating thickness of 2 mils (50 micrometers) on steel
sheet less than 0.0625 inches (in.) thick, 2.5 mils (63.5 micrometers) on steel sheet greater than
0.0625 in. thick or 0.75 mil (19 micrometers) on pre-galvanized steel sheet 0.0625 in. thick or
less. A material sample shall be capable of meeting or exceeding the corrosion resistance
provided by a galvanized sample (as described above) when subjected to the Mandrel Bend Test
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business