MIL-DTL-62027K
TABLE III. Classification of defects.
Methods of
Category
Defect
examination
Critical
None
Major:
101
Dissimilar metal not as specified (see 3.2.2).
Visual
102
Dimension not as specified (see 3.3).
SIE 1/
103
Malfunction; inoperative; damaged electrical system
Visual &
components (see 3.3.2).
Functional
104
Improper installation and easy removal of spare wheel
Visual &
(see 3.3.3).
Functional
105
Improper adjustment mechanisms; Failure to maintain
Visual &
adjustment within required setting (see 3.3.4).
Functional
106
Malfunction; improper control of electrical, mechanical
Functional
and hydraulic system (see 3.3.5).
107
Inoperative; improper installation of storage compartment
Visual
(see 3.3.6).
108
Improper bearings contamination; leaks (see 3.3.7).
Visual
109
Safety; Improper design and hazard to operating and
Visual
maintenance personnel (see 3.3.8).
110
Malfunction; inoperative lifting device (see 3.4.7).
Visual &
Functional
Minor:
201
Application, coverage or materials improper protective
Visual
coating (see 3.5).
202
Incomplete data; missing; improper location of decal
Visual
marking, data and instruction plates (see 3.6).
203
Improper lubrication; incomplete servicing (see 3.7).
Visual
204
Workmanship not as specified (see 3.8).
Visual
1/ SIE = Standard inspection equipment.
4.6.2.3 Adjustment mechanisms. To determine conformance to 3.3.4, all electrical,
mechanical, and hydraulic adjustment mechanisms shall be operated and examined for proper
adjustment, and adjusted if required.
4.6.2.4 Controls. To determine conformance to 3.3.5, all controls shall be operated and
examined for function during dolly set operation.
12
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business