MIL-DTL-62180F(AT)
SAE J2222
-
Coiled Electrical Cable, Technical Report
(Copies of these documents are available from www.sae.org or SAE Customer Service, 400
Commonwealth Drive, Warrendale, PA 15096-0001.)
UNDERWRITERS LABORATORIES, INC. (UL)
UL 711
-
Standard for Safety Fire Extinguishers, Rating and Fire Testing
(DoD Adopted)
(Copies of these documents are available from www.ul.com or Underwriters Laboratories,
2600 N.W. Lake Rd., Camas, WA 98607-8542.)
2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event
of a conflict between the text of this document and the references cited herein, the text of this
document takes precedence. Nothing in this document, however, supersedes applicable laws and
regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 First article (initial production) semitrailer. When specified (see 6.2), a sample shall
be subjected to first article inspection in accordance with 4.4 (see 4.3.1).
3.1.1 Durability. The semitrailer shall possess not less than 0.60 probability of
completing a minimum of 6000 miles of operation, without replacement or overhaul of major
components and/or subassemblies; i.e. suspension at full semitrailer load weight, axles and
wheels (less tires and tubes), brake system components (less brake shoes), landing gear, kingpin,
and tank shell or frame (based on binomial distribution assumptions). The criteria for
replacement or overhaul shall be as prescribed by the appropriate maintenance manual
(see 4.4.1).
3.1.1.1 Operational profile. The 6000 miles of operation, speed, and slope limitations
shall meet the requirements of 3.4.2 and 3 4.3.
3.1.1.2 Assembly(ies) Mean-Time-Between-Failure (MTBF). The assembly(ies)
(see 3.3.4) on the 5000-gallon tankers shall have a minimum MTBF of 100 hours when subjected
to requirements specified in 3.4 (see 4.4.2).
3.1.2 Maintainability. (See 4.4.3).
3.1.2.1 Maintainability requirements of basic semitrailer.
a. The total active combined scheduled and unscheduled maintenance of the
5000-gallon tankers (excluding driver/crew checks and services in accordance with
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business