TABLE II. Loading and unloading rates.
Operation and
Unloading rates
Loading rates
Unloading rates for other than diesel
Loading/unloading methods
semitrailer
(gal/min) for diesel
(gal/min) for fuel
fuels
configuration
fuels
Operation No. 1.
1.1.1. Loading: Automatic bottom
1.2.1. Up to 800
1.3.1. 175-225 gal/min
1.4.1. 175-225 gal/min, gravity
Bulkhauler
loading using external pump (other than
gal/min (external
gravity discharge, bulk
discharge, bulk delivery.
semitrailer s pump); or automatic
pump).
delivery.
bottom loading using gravity feed; or
1.4.2. 475-600 gal/min, bulk delivery
self-load using semitrailer s pump.
1.2.2. 250-300
1.3.2. 475-600 gal/min,
through pump.
gal/min (self-load
bulk delivery through
using semitrailer s
1.1.2. Unloading: Gravity discharge,
pump.
bulk delivery (unfiltered); or bulk
pump).
delivery (unfiltered) using external
pump; or bulk delivery (unfiltered)
using semitrailer s pump.
Operation No. 2.
2.1.1. Loading: Same as 1.1.1 above.
2.2. Same as 1.2.1
2.3.1. 40-60 gal/min
2.4.1. 40-60 gal/min (through one or
Automotive refueler
and 1.2.2 above.
(through one or both
both nozzles simultaneously)
2.1.2. Unloading: Fuel delivery through
NOTE: Filter
nozzles
automotive fuel servicing.
filter/water separator and automotive
separator and
simultaneously)
dispensing assembly using pump or bulk automotive fuel
automotive fuel
2.4.2. 80-100 gal/min (through
dispensing assembly
servicing.
delivery through filter/water separator
filter/water separator), or same as 1.4.1
with semitrailer s pump; or same as
are not used during
above.
unloading.
2.3.2. 80-100 gal/min,
1.1.2 above.
bulk delivery through
filter/water separator;
or same as 1.3.1 above.
Operation No. 3.
3.1.1. Loading: Same as 1.1.1 above.
3.2. Same as 1.2.1
N/A
3.4.1. Up to 300 gal/min (through large
Aircraft fuel servicing
and 1.2.2 above.
closed-circuit underwing nozzle)
underwing fuel servicing, 1/ or
semitrailer
3.1.2. Unloading: Fuel delivery through
NOTE: Filter
filter/water separator and
separator and
3.4.2. 80-100 gal/min through overwing
underwing/overwing dispensing
underwing/overwing
assembly using semitrailer s pump; or
fuel servicing or
fuel dispensing
same as 1.1.2 above.
assembly are not
3.4.3. 80-100 gal/min through small
used during loading.
closed circuit nozzle underwing fuel
servicing; 1/ or
3.4.4. Same as 2.4.2 above.
1/ Pump delivery with use of semitrailer s pump